Loading...
HomeMy WebLinkAboutapplication (411rff FOR OFFICE USE ONLY P&Z CASE NO.: OG"111(s DATE SUBMITTED: �`IRa4V CITY OF COLLEGE STATION \LY-A Planning eT'Development Services FINAL PLAT APPLICATION (Check one) ❑ Minor ❑ Amending ❑ Final ❑ Vacating I Replat ($300.00) ($300.00) ($400.00) ($400.00) ($600.00)* *Includes public hearing fee Is this plat in the ETJ? ❑ Yes ❑ No The following items must be submitted by an established filing deadline date for P&Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: X Filing Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet /4A Variance Request to Subdivision Regulations - $100 (if applicable) /./IA Development Permit Application Fee of$200.00 (if applicable). N/A Infrastructure Inspection Fee of$600.00 (applicable if any public infrastructure is being constructed) X Application completed in full. /4/1tCopy of original deed restrictions/covenants for replats (if applicable). Fourteen (14) folded copies of plat. (A signed mylar original must be submitted after staff review.) IA One (1) copy of the approved Preliminary Plat and/or one (1) Master Plan (if applicable). Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. x A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. NIA Two (2) copies of public infrastructure plans associated with this plat (if applicable). N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: N/A NAME OF SUBDIVISION C L LPEPPER PLAZA SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot& Block) L+or 2 ) &Lax, A t QICHARca t ARTA 1 A-B APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name STEVE tu11/41CAw � PI-EDGERKALkcA4 , /ijG. Street Address ROW Co4OrE Rte City L3Qr1 A 14 State TE-,(A S Zip Code 11 1308 E-Mail Address sedQ, pKe.mti he i t•%.corn Phone Number (999) 39) - WOO Fax Number MVO-491 - IsOU PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple owners): Name 1.ABRAJA CHAFIR1 Street Address J' 350 AL PNA RoA(J City DAu A S State TExA.S Zip Code 45240 E-Mail Address kt _nt cliff. 6rea,trsuf cora Phone Number (832.) S11 - 64452... Fax Number (9 12) ROI - 9 to &9 ARCHITECT OR ENGINEER'S INFORMATION: Name ALTON ROLvEras j 1✓ry&WE>:0-1 AI(.1 Street Address P.0 . °!a0 X 101[e 3 City Ct LLLE[,E STATION State Tex AS Zip Code FF B42 E-Mail Address 0.,rtvr5 eio ssriere.vicdNeert twecrui Phone Number Cct 941 ) 6$O —BB 40 Fax Number C9-44 ) & o —6841 6/13/03 Do any deed restrictions or covenants exist for this property? Yes No X Is there a temporary blanket easement on this property? If so, please provide the Volume 4A and Page# Acreage —Total Property 0.53$ Total#of Lots 10 R-O-W Acreage O Existing Use: CAPE N Proposed Use: T01.4/4/1aM E S Number of Lots By Zoning District / Q 3 Average Acreage Of Each Residential Lot By Zoning District: 0.538 / R Floodplain Acreage C A statement addressing any differences between the Final Plat and approved Master Plan and/or Preliminary Plat (if applicable): NIA Requested Variances To Subdivision Regulations & Reason For Same: /VIA Requested Oversize Participation: NIA Total Linear Footage of Parkland Dedication due prior to filing the Final Plat: Proposed Public: ACREAGE: Streets # of acres to be dedicated + $ development fee Sidewalks # of acres in floodplain Sanitary Sewer Lines # of acres in detention Water Lines #of acres in greenways Channels OR Storm Sewers FEE IN LIEU OF LAND: Bike Lanes / Paths # of Single-Family Dwelling Units X $556 = $ (date) Approved by Parks & Recreation Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct, and complete. The undersigned hereby requests approval by the City of College Station of the above-identified final plat and attests that this request does not amend any covenants or restrictions associated with this plat. X770 or Signatu - and Title Date 6/13/03 2 46 SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW CITY OF COLLEGE STATION Planning&Development Services FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) • 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. cg 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. g. 3. Title Block with the following information: • Name and address of subdivider, recorded owner, planner, engineer and surveyor. cgi Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) ® Date of preparation. Engineer's scale in feet. Egl Total area intended to be developed. 1g 4. North Arrow. ig 5. Subdivision boundary indicated by heavy lines. nN/A 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 'g 7. All applicable certifications based on the type of final plat. IZ Ownership and Dedication if Surveyor and/or Engineer El City Engineer (and City Planner, if a minor plat) El Planning and Zoning Commission (delete if minor plat) Brazos County Clerk El, Brazos County Commissioners Court Approval (ETJ Plats only) • 8. Paid tax certificates. 111 MA 9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. ❑NIA 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. ❑Nf A 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. Z 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. M 13. Matches the approved preliminary plat and/or master development plan. 6/13/03 4 of 6 xi 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed N jA El ❑ Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. ❑ Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) ❑ Street offsets and/or intersection angles meet ordinance. X ❑ Alleys. ❑ Easements. g ❑ A number or letter to identify each lot or site and each block. ❑ Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) ❑ 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed N f A by a Licensed Texas Professional Engineer that include the following: ❑ Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). ❑ Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) ❑ Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) ❑ Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. n Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. ❑ Drainage Report. ❑ Erosion Control Plan (must be included in construction plans). xi 16. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. 17. Are there impact fees associated with this development? ❑ Yes ❑ No Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing. Z 18. Will any construction occur in TexDOT rights-of-way? ❑ Yes ❑ No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NO I) must be submitted prior to issuance of a development permit. 6/13/03 5 of 6 D FOR fFI �E USE ONLY 56-1 P8Z C ENO.:OF W` ------ ---------- -- -- BATE SU MrITED: q ' 31(1.1t.1 CITY OF COLLEGE STATION I U'-0Q Planning d'Development Services I FINAL PLAT APPLIa, N (Check one) 0 Minor ❑ Amending ❑ Final ❑ Vacating X Replat ($300.00) ($300.00) ($400.00) ($400.00) (5600.00)` *Includes public hearing fee Is this plat in the ETJ? ❑ Yes X No The following items must be submitted by an established filing deadline date for P8Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: X Filing Fee(see above) NOTE: Multiple Sheets-$55.00 per additional sheet N/A Variance Request to Subdivision Regulations-$100(if applicable) N/A Development Permit Application Fee of$200.00(if applicable). N/A Infrastructure Inspection Fee of$600.00(applicable if any public infrastructure is being constructed) X Application completed in full. NIA Copy of original deed restrictions/covenants for replats(if applicable). X Thirteen(13)folded copies of plat. (A signed mylar original must be submitted after staff review.) N/A One(1)copy of the approved Preliminary Plat and/or one(1)Master Plan(if applicable). X Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. N/A Two(2)copies of public infrastructure plans associated with this plat(if applicable). N/A Parkland Dedication requirement approved by the Parks&Recreation Board, please provide proof of approval(if applicable). Date of Preapplication Conference: N/A NAME OF SUBDIVISION Culpepper Plaza SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot& Block)Lot 2.Block A,Richard Carter League,A-8 APPLICANT/PROJECT MANAGER'S INFORMATION(Primary Contact for the Project): Name Steve Duncan.Pledger Kalkomev.Inc. Street Address 7020 Coyote Run City Bryan State Texas Zip Code 77808 E-Mail Address sedapkenaineerinc.com Phone Number (979)791-8000 Fax Number (979)791-1500 PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple owners): Name Labraia Chafin Street Address 5350 Alpha Road City Dallas State Texas Zip Code 75240 E-Mail Address Iabraiatkatticusrealestate.com Phone Number (832)576-6932 Fax Number(972)-701-9639 ARCHITECT OR ENGINEER'S INFORMATION: Name Alton Rogers.Gessner Engineering Street Address P.O.Box 10763 City College Station State Texas Zip Code 77842 E-Mail Address aroiersttiaessnerengineerinQ.com Phone Number (9791680-8840 Fax Number (9791680-8841 6/13/O3 I of 6 Do any deed restrictions or covenants exist for this property? Yes -- - No X Is there a temporary blanket easement on this property?If so, please provide the Volume- -N/A and Page# Acreage-Total Property 0.538 Total#of Lots 1 R-O-W Acreage 0 Existing Use: OPEN Proposed Use: Townhomes Number of Lots By Zoning District 1 / R3 / / Average Acreage Of Each Residential Lot By Zoning District: 0.538 I R3 Floodplain Acreage 0 A statement addressing any differences between the Final Plat and approved Master Plan and/or Preliminary Plat(if applicable): N/A Requested Variances To Subdivision Regulations&Reason For Same: NIA Requested Oversize Participation: N/A Total Linear Footage of Parkland Dedication due prior to filing the Final Plat: Proposed Public: ACREAGE: Streets #of acres to be dedicated + $ development fee Sidewalks #of acres in floodplain Sanitary Sewer Lines #of acres in detention Water Lines #of acres in greenways Channels OR Storm Sewers FEE IN LIEU OF LAND: Bike Lanes/ Paths #of Single-Family Dwelling Units X$556 =$ (date)Approved by Parks & Recreation Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct, and complete. The undersigned hereby requests approval by the City of College Station of the above-identified final plat and attests that this request does not amend any covenants or restrictions associated with this plat. Signature and Ale Date Steve E.Duncan, P.E.,V.P. 6/13/03 2 of 6 (.*-ff" SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW CITY OF COLLEGE STATION Planning d.Development Services FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) ps 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 2 3. Title Block with the following information: 'Z Name and address of subdivider, recorded owner, planner, engineer and surveyor. 14 Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) 0 Date of preparation. EC Engineer's scale in feet. (:g Total area intended to be developed. RI 4. North Arrow. IX 5. Subdivision boundary indicated by heavy lines. 04,0 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 14 7. All applicable certifications based on the type of final plat. rg Ownership and Dedication I Surveyor and/or Engineer City Engineer(and City Planner, if a minor plat) ® Planning and Zoning Commission (delete if minor plat) [$ Brazos County Clerk gi Brazos County Commissioners Court Approval (ETJ Plats only) 8. Paid tax certificates. E(/el 9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. ❑N/A 10. If using private septic systems, add a general_note on_the.plat that no private_.sewage.facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. Opp 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. g 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. N, 13. Matches the approved preliminary plat and/or master development plan. 6/13/03 4 of 6 El 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed it)/4 ❑ Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. [x ❑ Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) VI ❑ Street offsets and/or intersection angles meet ordinance. EA ❑ Alleys. ❑ Easements. (I ❑ A number or letter to identify each lot or site and each block. ❑ Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P&Z Commission consideration.) 0 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed /JP by a Licensed Texas Professional Engineer that include the following: ❑ Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). ❑ Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) ❑ Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) ❑ Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. ❑ Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. ❑ Drainage Report. ❑ Erosion Control Plan (must be included in construction plans). M 16. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. 17. Are there impact fees associated with this development? 0 Yes Et No Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing. 53 18. Will any construction occur in TexDOT rights-of-way? _ ❑ Yes 2 No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent(NOI) must be submitted prior to issuance of a development permit. Sof6 6/13/03 4r1"1114.411414111 P&Z CASEFOR NO.:OFFICE USE ONLY CITY OF COLLEGE STATION • DATE SUBMITTED: Pknning&Development Services PRELIMINARY PLAT APPLICATION The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: )X Filing Fee of$400.00. )C Variance Request to Subdivision Regulations - $100 (if applicable) )C' Application completed in full. )C Fourteen (14)folded copies of plat. (A revised mylar original must be submitted after staff review.) A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. Rezoning Application if zone change is proposed. Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: Lot NAME OF SUBDIVISION of Z acil A ctrerpe Ana SIALt6A*A SPECIFIED LOCATION OF PROPOSED SUBDIVISION Gens FNSk por^:."•:2-t_ t - `)e/4-✓ Sket APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name //3iC4es1Py LP pI Street Address I7I2 f ' i 104 City �4qe SPL State Trip ZipCode �1-0o E-Mail Address ? m�! �Asnve4-Snee✓4.3 ,Gores Phone Number ( 14 (AO-¢,84o (Pi['C (02) Fax Number t17ti) l fto -k64-) PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple owners :, r Name S Q411 caJr r cechi-eS t tv t. ( Street Address 53oo P'� o,ryC 1),(1\4_ tv 4w City tiovc.l"r+n State Te/L(.S Zip Code 17007- E-Mail Address (710-3;? e )UtcdS ieJ(el:!,tr •tor\ Phone Number ((1'7) g44-944-4 Fax Number (113) 8bq--g4SO ARCHITECT OR ENGINEER'S INFORMT-ION: A (- [, Name kttr- tturvr ). S I V►r�t S A i&Y�c rS P4A h M `1 1 �`1 lhs Street Address 63S-0 A pkv City State T'UKG.S Zip Code x-5240 E-Mail Address NaNk e kJ S. GOA& Phone Number Ca'-2) 101 - 9(% Fax Number (crtz) 70 - 1 of4 6/13/03 Total Acres Of Subdivision Di c° R-O-W Acreage Total#Of Lots Number Of Lots By Zoning District Average Acreage Of Each Residential Lot By Zoning District: 5EE PLAT Floodplain Acreage I4/ Parkland dedication by acreage or fee? 14/k, A statement addressing any differences between the Preliminary Plat and approved Master PI an (if applicable) Requested variances to subdivision regulations& reason for sair e k '2k 245 le- L 21) 40ll AC+ 113re ,- o re-)-{ sd ha Requested oversize participation Parkland Dedication due prior to filing the Final Plat: ACREAGE: #of Acres to be dedicated #of acres in floodplain #of acres in detention #of acres in greenways OR FEE IN LIEU OF LAND: #of Single-Family Dwelling Units X$556 = $ (date)Approved by Parks & Recreation Board The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the above identified plat and attests that all respective owners have been identified on this application. J Nae" 2 200- Signat Title Date 2 01'4 6/13/03 EASEMENT DEDICATION SHEET To be filled in and submitted with construction plans and specifications for preliminary review (Not to be used where City is purchasing property) THIS SECTION TO BE COMPLETED BY CITY STAFF PROCESSED BY: DEPT. EXT. REQUESTED BY: DEPT. EXT. ACCOUNT NO. PROJECT NO. (For ordering title work,appraisals,etc.) TYPE OF EASEMENT: Public Utilities(PUE) Temporary Blanket PUE Electric Only (prior to building permit) Water Only PURPOSE FOR EASEMENT: REVIEW AND APPROVAL REQUIRED/GIVEN BY THE FOLLOWING DEPARTMENTS: Approval Required By: Electric Approval Given By: Electric (please initial) WaterNWV (please initial) WaterNWV Asst.City Engineer Asst.City Engineer Public Works Public Works METES&BOUNDS DESCRIPTION CHECKED FOR CLOSURE BY: (City Staff—Name/Dept.) THIS SECTION TO BE COMPLETED BY APPLICANT PROPERTY OVVNER(S): /e!-liievs lam 'f £/i? /he ry"��/ (Names must( be exactljas they appear on the deed) �[ /�/'/ ADDRESS: 53D / r e,flOf,d'C ��vel J�PPHONE NUMBER: ( /3) �� r — qY"�t 4" # .'S'►-, 7k ALL LENDERS(Please furnish copies of all lien documents): (Names and Addresses) IF OWNER IS A CORPORATION,PARTNERSHIP,OR JOINT VENTURE(also see#5 below): 1. State of Incorporation/Registration 2. Partners'Names(if applicable) 3. Person Authorized to Sign (Name and Title) LEGAL DEPARTMENT MUST BE PROVIDED WITH THE FOLLOWING: (PleaTck items that are attached) _ 1. A copy of a recent(within 90 days)deed or title insurance policy showing the names of the grantors/owners;and _ 2. For unplatted property, a signed, sealed and dated metes and bounds description and a diagram of the property showing the location of the easement;or _ 3. For platted property,a copy of the plat showing the lot,block,subdivision,and recording information. _ 4. For blanket easements, a signed,sealed and dated metes and bounds description and a diagram of the property. 5. Corporate or partnership owners must furnish a copy of a corporate resolution or other proof of authority to sign on behalf of the corporation,partnership,or joint venture. 6. Name,address and phone number of person who is to receive the easement and be responsible for getting It executed: Any land acquisition resulting from Capital Improvement Projects requires a meeting with the Legal Department. begs!:group deve ser applications 2003 easement dedication.doe ot,- 't' College Stomion Parks and Recreation Department Administrative Approval Form for Required Parkland Dedications Less than Three Acres 1. Applicant Name: Atticus Real Estate Services,Inc. Address: 5350 Alpha Road,Dallas,Texass 75240 Phone: E-mail: 2. Development Name:Lot 2,Block A,Culpepper Plaza Development Location:Northeast corner of G.Bush Drive and Dominik drive 3. Dwelling Units are in Park Zone 2 and are: Single Family Units 11 Multi-family Units 4. Required Land Dedication: .1089 Single Family @ 101 Dwelling Units per Acre Multi-family @ 125 Dwelling Units per Acre OR Fee: $ 2,178 Single Family @ $198.00 per Unit Multi-family @ $160.00 per Unit 5. Total Development Fee: $ 3,938 11 Single Family @ $358.00 per Unit Multi-family @ $292.00 per Unit Comments: $556 x 11= $6,116 total Parkland dedication fees College St. ion Parks & Recreation Department Approval: July 25,2006 Name Date 0:/Board/Park Land Dedication/PARD Approval Form for Less Than 3 Acres.doc