HomeMy WebLinkAboutStaff Review INDIAN LAKES F. ,ASE 10—PRELIMINARY PLAT RESPONSE TO STAFF REVIEW COMMENTS PLANNING 1. See attached revised Preliminary Plat. For the purposes of this preliminary plat, Phase 10 is tied to a point in Phase 8, labeled on the attached plat as "P.O.B." 2. See attached revised Preliminary Plat. 3. See attached revised Preliminary Plat. 4. See attached Variance Request. 5. This item will be handled with the construction drawings to be submitted along with the Final Plat. ENGINEERING 1. See attached revised Preliminary Plat. 2. As previously discussed, this Plat is vested within the old ordinances regulating street design criteria. 3. See attached revised Preliminary Plat. 4. As previously discussed, this Plat provides for a 16' Public Utility Easement in the fronts of all lots to satisfy the needs of utilities. Based on Brazos County regulations, a 20' Public Utility Easement, centered on all lot lines is required. With this Plat, 10' will be provided on all lot lines within Phase 10. Any lot abutting the phase boundary will provide for that lot's half of the required 20', the remaining 10' of the 20' Public Utility Easement will be provided when the adjacent property is platted. 5. The connection to Cherokee Road will be made when the growth of the development allows for such. FIRE 1. No comments. ELECTRICAL 2. No comments. 2/26/2006 Page 1 of 1 STAFF REVIEW COMMENTS NO. 2 Project: INDIAN LAKES PH 10 (PP) - 06-00500035 PLANNING 1. Please extend the match line so that it can easily be used. 2. The index sheet should show the individual lots and blocks. The purpose is to make the multi-page document easier to navigate once filed. Reviewed by: Jennifer Prochazka Date: March 2, 2006 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. 2 of 2 STAFF REVIEW COMMENTS NO. 1 Project: INDIAN LAKES PH 10 (PP) - 06-00500035 PLANNING 1. The plat needs to be tied to a College Station monument or known platted point. b-�(s 2. Please provide a 'match line' on both sheets. 3. Plats on multiple sheets require an index sheet at a scale of 1:500 or larger. — S 4. A block length variance will need to be requested for any block in excess of 1500'. I believe that the block south of Indian Lakes Drive does not meet this requirement. 5. A turn around will be required at the dead-end of Matoska Ridge. Reviewed by: Jennifer Prochazka Date: February 16, 2006 ENGINEERING ‘ -1. Note 16 is incorrect. The required ROW diameter is 100 feet, or radius 50 feet. The required pavement diameter is 80 feet, or radius 40 feet. A The new street design regulations require 100 feet ROW for a rural collector. 3. The plat does not close. Please rectify. Ok A 20' PUE is required on rear of lots abutting unplatted property. On , 5. When will the connection to Cherokee Drive be made? Reviewed by: Carol Cotter Date: February 13, 2006 FIRE 1. ETJ - No Comments Reviewed by: Steve Smith Date: 02/14/06 ELECTRICAL No Comments, BTU service territory To discuss any of the above electrical comments, please contact Gilbert Martinez at 979.764.6255. / Sam Weido at 979.764.6314. /Tony Michalsky at 979.764.3438. Reviewed by: Tony Michalsky Date: 2-14-06