HomeMy WebLinkAboutStaff Comments ENGINEERING COMMENTS NO. 2
Project: EDELWEISS GARTENS PH 7 (FP) —06-00500032
ENGINEERING
1. (Sheet 7) The sanitary sewer services crossing Renee Lane should be bored.
2. (Sheet 8) Please illustrate the water/sewer main conflict in profile view in
accordance to TCEQ standard.
3. (Sheet 10) Please illustrate the existing fire hydrant located on Renee Lane,
which will serve for fire coverage of the proposed lots adjacent to Renee Lane.
4. (Sheet 10) Please illustrate the water services crossing Renee Lane as needing
to be bored.
5. (Sewer Analysis) In Exhibit H, the actual slope of 12 to J2 does not match the
actual slope depicted in the profile construction documents.
Reviewed by: Josh Norton Date: May 2, 2006
STAFF REVIEW COMMENTS NO. 1
Project: EDELWEISS GARTENS PH 7 (FP) - 06-00500032
PLANNING/ENGINEERING
1. The construction documents and reports are still under review and may affect the
plat.
Reviewed by: Jennifer Reeves/Josh Norton Date: 02-20-06
FIRE
1. No comments
Reviewed by: Steve Smith Date: 02-14-06
ELECTRICAL
1. Developer installs conduit per city specs and design.
2. City will provide drawings for conduit installation.
3. Developer to intercept existing conduit at designated transformers and extend as
required.
4. If conduit does not exist at designated transformer, developer to furnish and
install conduit as shown on electrical layout.
5. Developer installs pull boxes & secondary pedestals as per city specs and
design.(pull boxes & secondary pedestals provided by the city).
6. Developer provides digital AutoCAD 2000 or later version of plat and/or site plan
email to sweido(c�cstx.gov
7. Developer provides easements for electric infrastructure as installed for electric
lines (including street lights).
8. Developer shall provide a 5' PUE for street lights at the following locations.
• Block 14 Lot 22 adjacent to Lot 23
• Block 14 Lot 42 adjacent to Lots 20 & 21
• Block 14 Lot 30 adjacent to Lot 31
• Block 14 Lot 34 adjacent to Lot 35
• Block 14 Lot 39 adjacent to Lot 40
• Block 14 Lot 38 adjacent to Lot 37
To discuss any of the above electrical comments, please contact Sam Weido at
979.764.6314.
Reviewed by: Sam Weido Date: 2-16-06
NOTE: Any changes made to the plans,that have not been requested by the City of College Station,must be explained
in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not
been pointed out to the City,will constitute a completely new review. 2
STAFF REPORT
Project Manager: Jennifer Reeves, Staff Planner Report Date: March 2, 2006
Email: jreeves@cstx.gov Meeting Date: March 16, 2006
Project Number: 06-00500032
Item: Public hearing, presentation, possible action, and discussion on a Replat
of Bald Prairie Lots 4&5 and a Final Plat of Edelweiss Gartens Phase 7
consisting of 50 lots on 10.715 acres located off of Eagle Avenue east of
Brandenburg Lane.
Applicant: Steve Arden, Developer Owner
Staff Recommendations: Staff recommends approval of the Final Plat and
Replat as submitted.
Item Summary: This item is set for a Public Hearing because a section of the
subject property involves a Replat of a portion of the Bald Prairie Subdivision.
The original plat for Bald Prairie was filed in 1973. All proposed lots meet the
minimum standards of the Subdivision Regulations and are being platted to meet
R-1 standards as allowed by the UDO.
Comprehensive Plan Considerations: The Land Use Plan shows this area to
be Single Family Medium Density. Eagle Avenue is shown as a Minor Collector
on the Thoroughfare Plan.
Item Background: The subject property was annexed into the City of College
Station City Limits June of 1995 and was rezoned from A-O Agricultural Open to
R-1 Residential Single Family in March of 2005. Bald Prairie Lots 4&5 were
platted in 1973.
Related Advisory Board Recommendations: Park Land dedication
requirements are being met with land dedication. Park Land Development fee for
this phase will be $358 per dwelling unit or $17,900. These fees will be due at
the time the plat is filed.
Commission Action Options: The Commission has final authority over the final
plat. The options regarding the final plat are:
• Approval, or
• Denial
Supporting Materials:
1. Small Area Map (SAM) and Aerial Map
2. Application
3. Copy of Final Plat (provided in packet)
Grffil511111114
CITY OF COLLEGE STATION
Planning&Development Services
CITY OF COLLEGE STATION
PLANNING & DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone (979)764-3570 / Fax (979)764-3496
TO: JOSH ISENHOUR
RE: PONDEROSA PLACE#2-REZONING
FAX: 979-268-6841
FROM: Lisa Lindgren, Staff Assistant
DATE: March 14, 2006
RE: Agenda Sc Staff Report
P&Z Meeting, March 16, 2006
Following this coversheet is a copy of the Staff Report that was prepared for the above
referenced project. Please keep in mind that staff's responsibility is to provide the
Planning & Zoning Commission with all pertinent facts of a development case, but that
staff is not acting as an advocate for the applicants. Therefore, it is in the applicant's best
interest to send a representative to the Planning & Zoning Commission meeting to speak
on behalf of the proposal.
This item is scheduled for the March 16, 2006, Planning & Zoning Commission
Meeting. This meeting will begin at 7:00 P.M. in the City Hall Council Chambers., 1101
Texas Avenue. I have included a copy of the agenda for this meeting. Please contact our
office at (979) 764-3570 if you should have any questions. Thanks.