Loading...
HomeMy WebLinkAboutApplication (*,1444 FOR OFFICE USE ONLY/ P&Z CASE NO.: 01' 3 3 DATE SUBMITTED: f ' I 0 'Vi Q CITY OF COLLEGE STATION •. 0 Planning&Development Services l t FINAL PLAT APPLICATION (Check one) n Minor ❑ Amending V Final n Vacating n Replat ($300.00) ($300.00) ($400.00) ($400.00) ($600.00)* `Includes public hearing fee Is this plat in the ETJ? I I Yes n No The following items must be submitted by an established filing deadline date for P&Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: N/A $300 - $600 Filing Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet N/A $100 Variance Request to Subdivision Regulations (if applicable) N/A $200 Development Permit Application Fee (if applicable). N/A $600.00 Infrastructure Inspection Fee (applicable if any public infrastructure is being constructed) ✓ Application completed in full. N/A Copy of original deed restrictions/covenants for replats (if applicable). ✓ Fourteen (14) folded copies of plat. (A signed mylar original must be submitted after staff review.) N/A Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. ✓ A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. Two (2) copies of public infrastructure plans associated with this plat (if applicable).(previously submitted) N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: NAME OF SUBDIVISION Lot 2, Block 1 College Station ISD, Graham Rd. School Site 4.SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot&rjAcjc),�Sou of Gra.ham Rd. School Site APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for e Project):e Name Veronica J.B. Morgan, Mitchell & Morgan, LLP Street Address 511 University Drive East, Suite 204 City College Station State Texas Zip Code 77845 E-Mail Address v( mitchellandmorgan.com Phone Number (979) 260-6963 Fax Number (979) 260-3564 PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple owners): Name College Station ISD-Jon Hall Street Address 2000 Welsh Avenue City College Station State Texas Zip Code 77840 E-Mail Address ihall@csisd.orq Phone Number (979) 694-5610 Fax Number (979) 694-5612 ARCHITECT OR ENGINEER'S INFORMATION: Name Steve Aloway, VLK Architects Street Address 7915 FM 1960 Road West City Houston State Texas Zip Code 77070 E-Mail Address alowayAvlkarchitects.com Phone Number (281) 671-2300 Fax Number (281) 671-2300 Do any deed restrictions or covenants exist for this property? Yes No ✓ Is there a temporary blanket easement on this property? If so, please provide the Volume N/A and Page# Acreage -Total Property 29.93 acres Total#of Lots 1 R-O-W Acreage 1.70 acres Existing Use: Vacant Proposed Use: Elementary School Number of Lots By Zoning District 1 / A-O / / Average Acreage Of Each Residential Lot By Zoning District: N/A / / / / Floodplain Acreage 3.2 acres A statement addressing any differences between the Final Plat and approved Master Plan and/or Preliminary Plat(if applicable): None Requested Variances To Subdivision Regulations & Reason For Same: None Requested Oversize Participation: Street OP will be requested Total Linear Footage of Parkland Dedication due prior to filing the Final Plat: Proposed Public: ACREAGE: 1050.5 LF Streets N/A # of acres to be dedicated + $ N/A development fee 2080 LF Sidewalks N/A # of acres in floodplain 0 Sanitary Sewer Lines N/A # of acres in detention 1135.1 LF Water Lines N/A # of acres in greenways 0 Channels OR 766.85 LF Storm Sewers FEE IN LIEU OF LAND: 2080 LF Bike Lanes / Paths N/A # of Single-Family Dwelling Units X $556 = $ N/A N/A (date) Approved by Parks & Recreation Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, cor -,t, and complete. The undersigned hereby requests approval by the City of College Station of the above-identified fin: • at and attests that this request does not amend any covenants or restrictions associated with this plat. i ' I:kalif& Mk 1.- L, , 1410/0'1 Signature and Titi! 1 4 tV Date 4-ff SUBMIT APPLICATION AND THIS CITY OF COLLEGE STATION LIST CHECKED OFF WITH 13 Planning&Development Semites FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) FUr 1. Mylar original of ap ro ed prelimiry+plat (M I r must be on file or submitted before the final plat will be reviewed). � 1" J 2. Paid tax certificates. IR' 3. Drawn on 24" x 36" sheet to scale of 100' per inch. R7 4. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 5. Title Block with the following information: I el' Name and address of subdivider, recorded owner, planner, engineer and surveyor. [ ' Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) Date of preparation. I✓' Engineer's scale in feet. R' Total area intended to be developed. F' 6. North Arrow. [✓ 7. Subdivision boundary indicated by heavy lines. hPc 8. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 0 9. All pplicable certifications based on the type of final plat. [' Ownership and Dedication Fr Surveyor and/or Engineer Er City Engineer (and City Planner, if a minor plat) Planning and Zoning Commission (delete if minor plat) Brazos County Clerk IV Brazos County Commissioners Court Approval (ETJ Plats only) 10. If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. ItA 11. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. I 12. Location of the 100-Year Floodplain and floodway, if applicable, according to the most recent available data. VI 13. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. 14. Matches the approved preliminary plat and/or master development plan. 15. The location ana description with accurate dimensions, uearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. F.7 Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) a EJ Street offsets and/or intersection angles meet ordinance. tOTA VIA Alleys. [ Easements. (-- A number or letter to identify each lot or site and each block. IEVI Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) RI 16. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: 1-0'' Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). Sewer Design Report. Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Water Design Report and/or Fire Flow Report. Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) I-✓ Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. I Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. I—✓ Drainage Report with a Technical Design Summary. [r Erosion Control Plan (must be included in construction plans). lif; 17. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. 18. Are there impact fees associated with this development? ❑ Yes ✓n'No Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing. R 19. Will any construction occur in TexDOT rights-of-way? n Yes RNo If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereb made for the followinq development, pecific site/waterway alterations: () Atak ' Itli9N/KCla -,-c_Y----6,-o e/uJ4.-ekt vi-61/k (Pk. ACKNOWLEDGMENTS: I, \)12)01C/Q) {(21 t`' design engineer/owner, hereby acknowledge or affirm that: The information and conclusions ntained in the above plans and supporting documents comply with the current re• ements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Sta tards. As a condition of approval of this permit application, I agree to construct the improvements proposed in this alp.(i .tion a/SO t. these documents and the requirements of Chapter 13 of the College Station City Code. 4 11/ I /SO t Property Owner �� LU` Contractor r CERTIFICATIONS: (fo •roposed alterations within designated flood hazard areas.) A. I y� ��1� 1 ) „s.«�. tlpti1 any nonresidential structure on or proposed to be on this site as of this application is design_• to & n a . tR the structure or its contents as a result of flooding from the l rear sto�n, �,%*:••• '' :*lei � �.............. �.�.B.............................................. ORGAN i 1'2►(� C I Engineer �' �. ............ .7 i l -o•.• 77689 689 :id, • Date 4P1 /�P 90` 9F PQp• ��(/�B. I. tti 4s.'•• i • _4he finished floor elevation of the lowest floor, including any basement, of any residential structure, pr O ---of this application is at or above the base flood elevation established in the latest Federal Insurance Administiion Flood Hazard Study and maps, as amended. Engineer Date C. I, VQA/61469v t / % ,. �`�� �t'$,. .,„. till the alterations or development covered by this permit shall not ,iminish the flood-carrying c-..citye•'w .t.e ay•. c; d ing or crossing this permitted site and that such alterations or ,,:velopment are consistent with Oatuireme' of th.Ocip of College Station City Code, Chapter 13 concerning enc s;:chments of loodways and of flo¢eagp�lfjlpogg.S. MORGAN s • ,P , ak/1 f` -o... 77689 •'r : q4(.7 '1 Engin--r I ^�A, ?, •GrSTEP.. Date �Xiv uu �. 9 jo s/ONA�v—”'. D I x/��b -c reify that the proposed alterations do not raise the level of the 100 -i flood elev-tion estal�li ed ir) ti t.Jt ..•.4. .1n,,,Insurance Administratio Flood Hazard Study. ' ir; I / ►� : ,1 *jib ,k(0 ^ _ -va kv r'w-� -"�• • p•- cfy– co Engineer �') i VERONICA J.B.MORGAN i Date I I C `` Conditions or commen as part of ap 'al: 77689 0 . ' l..a\ss'/VNAL,�C?a In accordance with Chapter 13 of the Code o'° rices of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply.