Loading...
HomeMy WebLinkAboutStaff Report CITY OF COLLEGE STATION PRELIMINARY PLAT FOR HARVEY MITCHELL COMMERCIAL SUBDIVISION 08-00500238 SCALE: 4 lots on 8.255 acres LOCATION: 1981 Harvey Mitchell Parkway, located adjacent to the electric substations opposite the intersection with Rio Grande Blvd ZONING: C-3 Light Commercial, R-3 Townhouse, R-1 Single Family Residential, and A-O Agricultural Open APPLICANT: Mike Butte, Z-Co. Development PROJECT MANAGER: Jason Schubert, AICP, Staff Planner jschubert@cstx.gov RECOMMENDATION: Approval Page 1 of 4 Planning&Zoning Meeting November 6, 2008 wriwormiromaimmialmour tomkk Zg QOM w �s „> ,1„)S dI MO p sS„ Nb O� S Oc .9 Q ct 0” w 4W A. ��� 2 � '�,Vi �.I!�- bpi 5 .,- 8 oil 4s' • dp f w Rio G p''_ JO I w W i 0 y J �� Lu 5J� w 1- 0 Y ���y 1 ( NORG ST ,. \ GF rte, a -- Page 2 of 4 Planning&Zoning Meeting November 6,2008 0 DEVELOPMENT HISTORY Annexation: 1969 Zoning: C-3 Light Commercial, R-3 Townhouse, and A-O Agricultural Open (1978); R-1 Single Family Residential (1969) Site development: Vacant with a single-family dwelling on Lot 11. COMMENTS Water: The subject tract is located adjacent to a 24-inch water main, which runs along the northern side of Harvey Mitchell Parkway. This preliminary plat illustrates the future extension of an 8-inch water line to serve Lot 2, Block 2. Sewer: The subject tract is located adjacent to a 21-inch sanitary sewer main, which runs along Bee Creek Trib. B just opposite this property. This preliminary plat illustrates the future extension of a 6-in sanitary sewer line to serve all 3 proposed lots. Streets: The subject property has frontage along Harvey Mitchell Parkway, a Major Arterial on the City's Thoroughfare Plan. Since TxDOT maintains Harvey Mitchell Parkway, a TxDOT driveway permit will be required to construct any access to this property. This preliminary plat does illustrate the future extension of a minor collector roadway (Minar Court) to serve Lot 2, Block 2. Off-site Easements: None known at this time. Drainage: The subject tract is Located within the Bee Creek Trib. B drainage basin. Development of this tract will be required to meet all City Drainage Guidelines. Flood Plain: The subject tract is encroached by a Special Flood Hazard Area —Zone AE (base flood elevations determined), per FEMA FIRM Panel 182C. The City has recently completed a capital improvement project on the Bee Creek watershed adjacent to this tract. The project's associated flood study is still under way, and the final limits of a revised 100-year floodplain boundary have not been submitted to or adopted by FEMA. Oversize Request: None known at this time. Parkland Dedication Fees: Currently, none is required. If Phase 2 is subdivided in the future for townhouse lots, then parkland dedication requirements would apply. Impact Fees: None. REVIEW CRITERIA 1. Compliance with Comprehensive Plan and Unified Development Ordinance: The Comprehensive Land Use Plan designates the majority of the subject area as Planned Development and Floodplain & Streams with Lot 11, Block 14 of Southwood Section 25 being largely designated as Single Family Residential Medium Density. However, the property is already zoned C-3 Light Commercial along Harvey Mitchell Parkway, R-3 Page 3 of 4 Planning&Zoning Meeting November 6, 2008 0 Townhouse in the middle portion, A-O Agricultural Open along Bee Creek and Lot 11 being zoned R-1 Single Family Residential. The property has frontage on Harvey Mitchell Parkway, a major arterial on the Thoroughfare Plan. Bike paths are proposed on the Bikeway and Pedestrian Plan along Harvey Mitchell Parkway and Bee Creek. The applicant is providing a 12-foot wide public access easement along Harvey Mitchell Parkway to accommodate the proposed sidewalk and future bike path. Any future bike path along Bee Creek will be located along the western side, or opposite side, of the creek from this property so no easement or dedication is required for this plat. 2. Compliance with Subdivision Regulations: The preliminary plat complies with the Subdivision Regulations. The plat proposes that a future replat of Lot 11, Block 14 Southwood Section 25 will incorporate the 0.363 acre area of the existing tract to provide additional buffer from future development of this tract. The remaining area of the tract is proposed in 2 phases which are separated along the C-3 Light Commercial and R-3 Townhouse zoning boundary. STAFF RECOMMENDATION Staff recommends approval of the preliminary plat. SUPPORTING MATERIALS 1. Application 2. Copy of Preliminary Plat (provided in packet) Page 4 of 4 Planning &Zoning Meeting November 6, 2008