HomeMy WebLinkAboutStaff Comments C**ff111144 CITY OF COI.J.FGE STATION Planning d Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570/Fax 979.764.3496 MEMORANDUM December 13, 2007 TO: Thomas Gessner, Gessner Engineering, via fax 680.8841 FROM: Lindsay Boyer, AICP, Senior Planner SUBJECT: WATERFORD HEIGHTS PH. 1 (PP) - Preliminary Plat Staff reviewed the above-mentioned Preliminary Plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Monday, December 31st, 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for Thursday, January 17th, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24" x 36" copy of the revised Preliminary Plat; and Nineteen (19) 11" x 17" copies of the revised Preliminary Plat. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed, your project will be pulled from the scheduled Planning & Zoning Commission agenda. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.cstx.gov/home/index.asp?page=2481. Please note that a Mylar original of the revised preliminary plat will be required after P&Z approval and prior to processing subsequent final plats. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Tony Jones, Phi-Ton Investments, L.P., via fax 695.2941 I/ Case file #07-00500312 STAFF REVIEW COMMENTS NO. 1 Project: WATERFORD HEIGHTS PH. 1 (PP) - 07-00500312 PLANNING 1. Plat is missing a call along south of the phase boundary for closure. 2. Revise and resubmit page 2 of the application. The total acreage for this phase is 37.43 acres. What is the acreage of R-1 in this phase? It shows 020. I'm guessing it is 24.43. 3. What is the status of the compressor station, it does not become R-1 until the entire site is removed and abandoned. 4. Parkland development fees will be required if the park is not developed privately. 5. Show city limits in key map. 6. It would be possible to combine phases 1 and 2 in one preliminary plat. 7. Remove Note 14. 8. Clearly delineate Greens Prairie Road ROW dedication. 9. Provide thoroughfare classification for Waterford Drive and Greens Prairie Road. 10.Provide note that no residential driveways shall take access from Waterford Drive or Greens Prairie Road. 11.What is the purpose of the bold lines on along the ROW? They make it difficult to locate the sidewalk, and define the phase line. 12.AlI roads should state the name, the ROW width and the pavement width, i.e., Brazos Landing Drive 50' ROW 27' pavement 13.Where are fire hydrants? 14.Sidewalks are required along Greens Prairie Road (8-M of the Subdivision Regulations). Provide or request a variance. 15.What is the block length for Waterford Drive between Victoria and Cross Creek? 16.Lot 3 and 4, Block 6 do not meet minimum R-1 zoning lot dimensions. Also Lot 9, Block 5. Reviewed by: Lindsay Boyer Date: December 13, 2007 ENGINEERING COMMENTS NO. 1 1. Having prior rights and being allowed to go in another entity's easement (Note 9) are not the same thing. The City requires prior rights so we will not have to relocate utilities at the request of the easement owner. 2. Even if "first rights" were assigned to the City of College Station by the existing easement owners, there are a number of underground lines in the easements along Greens Prairie Road which would make dedicating a PUE on top of the existing easements and placing additional infrastructure in the easements highly improbable. This is one of the reasons that Castlegate has the large Common/Buffer Area along Greens Prairie Road. You should take this into consideration in your design. 3. The words "Preliminary Plat— Not for Record" are required to be in letters 'A" high. 4. Why not combine Phases 1 and 2 into a single Preliminary Plat? You can Final Plat each phase separately off the Preliminary. 5. State the number of lots and corresponding blocks in Title Block. 6. Show all existing easements and provide volume and page numbers. 7. Unless there is a Preliminary Plat showing the remaining 10' of the required 20' PUE along rear of all lots, then the entire 20' PUE is required along rear of lots abutting unplatted property. 8. Some of your leader notes are cut off on right hand side of plat. 9. Woodlake subdivision is noted in the wrong location. 10. All of the lines along Greens Prairie Road are too difficult to decipher. 11. It appears that your plat boundary creates a strip of "no mans land" around perimeter of the plat. Boundary should follow legal lot lines and/or right-of-way 12. Public utilities need to be out from under pavement where practical. 13. You have more water and sanitary sewer lines proposed than necessary to serve this development. Many of the lots have sewer and water along the front and back. Why is there a water line and sanitary sewer line along greens Prairie Road? 14. Is sanitary sewer line along green's Prairie connected to line in Waterford Drive? 15. More clearly define the storm sewer layout. 16. Remove proposed gas line delineation from Preliminary Plat. There are too many lines in the area of the water line, so it is hard to tell what is proposed. 17. Your legend shows "SS" for proposed sanitary sewer, but the plat shows "S". I am assuming both denote sanitary sewer. 18. Indicate proposed preliminary water and sanitary line sizes. 19. Water line between Lots 3 and 4, Block 6 needs to be in PUE. So do water and sewer along Greens Prairie Road. 20. Show fire hydrant locations. Ensure they meet spacing requirements. 21. A portion of this development is located in the Spring Creek Sewer Impact Fee Area 97- 01. Impact fees are due at time of building permit. 22. Verify the horizontal alignment meets design criteria for respective street classifications. 23. Show that all intersections have appropriate sight distances in accordance with latest addition of AASHTO's "A Policy on Geometric Design of Highways and Streets". 24. Additional comments may arise with revised submittals. Reviewed by: Carol Cotter Date: December 21, 2007 ADDRESSING 1. Rename Waterford Drive (Waterford already exist in the City) 2. Change suffix of Brazos Landing Drive to Court (Blk 3) 3. Rename Riverstone Street (already exist in the City) 4. Change suffix of Creek Crossing Street to Court 5. Rename River Court (already exist in City) Reviewed by: Mandi Alford Date: 12/13/07 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. Developer provides temporary blanket easement for construction purposes. 2. Developer provides easements for electric infrastructure as installed for electric lines (including street lights). 3. Additional easements may be requested as an electric distribution plan is developed for this phase. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per City specs and design. 2. City will provide drawings for conduit installation. 3. Developer provides 30' of rigid or IMC conduit for riser poles. City installs riser. 4. Developer to intercept existing conduit at designated transformers and extend as required. 5. If conduit does not exist at designated transformer, developer to furnish and install conduit as shown on electrical layout. 6. Developer pours transformer pad(s) per City specs and design. 7. Developer installs pull boxes and secondary pedestals as per City specs and design (pull boxes and secondary pedestals provided by the City). 8. Developer provides digital AutoCAD 2000 or later version of plat and/or site plan. Email to bread@cstx.gov. 9. Developer provides load data for project. 10. To discuss any of the above electrical comments please contact Brent Read at 979.764.5026. Reviewed by: Brent Read Date: December 19, 2007 FIRE 1. Main road should be complete to Victoria before thirty (30) dwellings are built. Reviewed by: Steve Smith Date:12/12/2007 SANITATION 1. Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: December 11, 2007