Loading...
HomeMy WebLinkAboutStaff Comments 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM January 10, 2008 TO: Ross Albrecht, via email FROM: Lindsay Boyer, AICP, Senior Planner SUBJECT: COCS MEMORIAL CEMENTERY BLK 1 (FPCM) - Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Monday, January 21st, 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for Thursday, February 7, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24"x36" copy of the revised final plat; Nineteen (19) 11"x17" copies of the revised final plat; Certified tax certificates; One (1) copy of the digital file of the final plat on diskette or e-mail to mtrevino@cstx.gov; and The Mylar original of the revised final plat with the owner and County Judge's signatures (will be required after the County's approval). Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed, your project will not be scheduled for the Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.cstx.gov/home/index.asp?page=2481 Please note that a Mylar original of the revised final plat will be required after P&Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments cc: Michael Martin, Jacobs Edwards & Kelcey, via fax 764-9228 Gary Arnold, Brazos County Planning & Traffic, via fax 775.0453 Case file #07-00500341 STAFF REVIEW COMMENTS NO. 1 Project: COOS MEMORIAL CEMENTERY BLK 1 (FPCM) - 07-00500341 PLANNING 1. Tax certificates are required by the County in order to file the plat. Certificates are issued from Brazos County Appraisal District. 2. Where are the access easements that are shown on the preliminary plat? They need to be clearly labeled as proposed easements and shown on the plat. 3. Remove all previous lot boundaries and ownership notation for each lot. 4. What is the purpose of having the league line on the plat? 5. What is the purpose of having the axis of symmetry on the plat? It would be much cleaner to lable the curves and provide a curve table with the measurements instead. 6. Why are there three separate plats? The entire lot can also be platted with Section MC!, IN1, and FH1 in one document. This will reduce the city cost of filing 3 separate plats at the courthouse. Otherwise, the two section plats will be replats. 7. Preliminary plat mylar must be provided after it is approved by P&Z. 8. Remove the heavy line on the north side of the property west of the Williams property on Raymond Stotzer. 9. Clearly show zoning district boundaries for the subject tract. 10. Please use the standard certificate language for ownership certificate found in Appendix A of the subdivision regulations Reviewed by: Lindsay Boyer Date: January 4, 2008 ENGINEERING COMMENTS NO. 1 1. Please submit 2 full size sets of the plan and profile construction documents for the on-site and off-site public water main and public sanitary sewer main extensions. These construction documents and their review is a requirement for taking the final plats of the COOS Memorial Cemetery forward to P&Z. 2. Please verify that there are no off-site easements needed to construct the proposed water and sewer main extensions. Reviewed by: Josh Norton Date: January 7, 2008 SANITATION 1. Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: January 7, 2008 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. Developer provides temporary blanket easement for construction purposes. None required since it is City of College Station property. 2. Developer provides easements for electric infrastructure as installed for electric lines (including street lights). None required since it is City of College Station property. 0 3. If applicable, the following easements will be required: We are waiting on an easement on the Raiford Williams property. If we are not able to procure it, the underground electrical lines will need to rerouted and adjusted to accommodate the development. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per City specs and design. 2. City will provide drawings for conduit installation. 3. Developer provides 30' of rigid or IMC conduit for riser poles. City installs riser. 4. Developer to intercept existing conduit at designated transformers and extend as required. 5. If conduit does not exist at designated transformer, developer to furnish and install conduit as shown on electrical layout. 6. Developer pours transformer pad(s) per City specs and design. 7. Developer installs pull boxes and secondary pedestals as per City specs and design (pull boxes and secondary pedestals provided by the City). 8. Developer provides digital AutoCAD 2000 or later version of plat and/or site plan. Email to: wdavis@cstx.gov. 9. Developer provides load data for project. 10. To discuss any of the above electrical comments please contact Weldon Davis at 979.764.5027. Reviewed by: Weldon Davis Date: January 3, 2008